- Welded frame made of 4"x4"x1/4"wall steel tubing
with a ¾" thick Blanchard ground top plate
- Machine frame is powder coated
- Machine frame has adjustable legs for easy height adjustment plus
adjustable leveling feet for making fine adjustments.
- Operator Station with PLC Interface makes part changes quick and
easy with recipe function while providing machine diagnostics for
quick troubleshooting
- Heat manifolds are powder coated
- Gas Flowmeter and Manifold Manometer to verify process settings
- Air and water cooling valve timers adjustable through Operator Interface
and are unique to recipe code
- Needle Valves installed on all air and water cooling outlets
- Individual gascocks installed for each burner to allow individual
flow adjustments or to turn burners on and off depending on part being
processed
- Stainless Steel tubing used for burner pattern provides rigidity
- All utility connections located together
- Color-coded piping for gas lines, air lines, and water lines
- Air dump valve with lockout for main air supply
- Lockable Electrical Panel Disconnect
- Hi/Lo Heat System conserves fuel by switching to low settings when
parts are not loaded
- Isolation valves installed on incoming air and fuel source lines
- Weiss Cam-Driven Indexer
- 0.75" Thick Aluminum Toolplate
- Stainless Steel Toolplate Cover
- Stainless Steel Water Trough
- Safety pressure switches on heat system detect low gas pressure,
high gas pressure, and low air pressure
- Proximity switches installed on extend and retract positions of
all slides
- Flow Controls installed on all cylinders and slides
- Air dump valves installed on all slides to assist with setups and
adjustments
- Paste tanks supplied with quick-release lid clamps
- Paste guns controlled through the PLC to allow paste adjustment
through the PLC recipe feature
- Manual paste purge pushbuttons supplied for each paste gun
- 1 spare paste gun supplied for each paste gun used
- Free servicing of paste guns when Fusion paste products are used
- Allen-Bradley SLC 5/03 PLC with a Panel View 550 Operator Interface
- 24VDC control voltage
- Quick Disconnects on proximity switches, pressure switches, and
solenoid valves to make maintenance quick and simple.
|