Instructions for Proper Use
Paste
Alloys Applicator Systems Automated Equipment
PASTE
HANDLING & STORAGE*
STORAGE
- Store paste
in an area shielded from extreme heat and cold. Ambient temperatures
from 55 ° F to 75° F (13° C to 24° C) are recommended.
- Do not
store near open flames or sources of high heat.
- Rotate
paste stock, using "first in/first out" procedure.
Nominal shelf life period is six (6) months for paste in the
jars, three (3) months for cartridges.
STIRRING
- Before
loading paste into reservoir, gently stir with a spatula using
a lifting motion to insure complete homogeneity. This mixing
should be done even if no separation or layering is apparent.
Metal spatulas should be avoided because they can cut bits of
plastic from the container and leave them in the paste. DO NOT
MIX WITH POWER MIXER WITHOUT CONSULTING WITH THE FACTORY.
- Do not
attempt to thin paste with outside dilutents! Adverse chemical
reactions may occur!
PROPER
USE
- Read and
understand the product MSDS before use.
- Keep paste
jar sealed until time to use. If jar's contents not completely
emptied, tighten lid to prevent extended air exposure. (For
best results, paste should be used within a week of opening
sealed jar.)
- Do not
re-use paste jar when empty.
- Use minimum
paste pressure (in applicating system), and the shortest length
of paste hose. Use largest possible diameter nozzle, which has
the shortest extension length.
- Solder
or braze in a well ventilated area.
- Wash paste
from skin with soap and water, or waterless hand cleaner.
*These are general guidelines
for all Fusion Pastes;
please consult the container label for
specific instructions.
[ About Fusion || Filler Metals/Fluxes || Applicator
Equipment || Automatic Machines ]
[Cleaning Tips || Dispensable
Fluxes || Contact Us ]
[ brazing || soldering || filler metal || brazing
paste || solder paste || fluxes || pallet
conveyor ]
[ silver brazing || brazing
system || automatic
brazing machine || automation equipment || pick
and place ]
|