- Operator Station
with PLC Interface makes part changes quick and easy while providing
machine diagnostics for quick troubleshooting
- Quick-Disconnect
manifolds require no tools to change making part changeovers quick
and easy
- Heat manifolds
are powder coated
- Fully adjustable
manifold position makes machine configurable for most applications
- Gas Flowmeter
and Manifold Manometer to verify process settings
- Heat, Air Cooling,
and Water Cooling time adjustable through Operator Interface
- Needle Valves
installed on all air and water cooling outlets
- Individual gascocks
installed for each burner to allow individual flow adjustments or
to turn burners on and off depending on part being processed
- Stainless Steel
tubing used for burner pattern provides rigidity
- Guarding provides
safety and process stability be shielding from air currents
- Polycarbonate
windows allow for good visibility
- Banner Two-Hand
safety switches assure operator is clear of machine
- All guard doors
hinged for easy maintenance
- All utility connections
located together
- Color-coded piping
for gas lines, air lines, and water lines
- Air dump valve
with lockout for main air supply
- Hi/Lo Heat System
conserves fuel by switching to low settings between cycles
- Isolation valves
installed on incoming air and fuel source lines
- Oscillating Heat
Slide with adjustable stroke spreads heat throughout the joint area
evenly
- Stainless Steel
Water Trough
- Access Door for
heat system adjustments
- Safety pressure
switches on heat system detect low gas pressure, high gas pressure,
and low air pressure
- Proximity switches
installed on extend and retract positions of all slides
- Flow Controls
installed on all cylinders and slides
- Air dump valves
installed on all slides to assist with setups and adjustments
- Paste tanks supplied
with quick-release lid clamps
- Paste guns controlled
through the PLC to allow paste adjustment through the PLC
- Manual paste
purge pushbuttons supplied for each paste gun
- 1 spare paste
gun supplied for each paste gun used
- Free servicing
of paste guns when Fusion paste products are used
- Allen-Bradley
MicroLogix PLC with a MicroView Operator Interface
- 24VDC control
voltage
- Quick Disconnect
on proximity switches, pressure switches, and solenoid valves to make
maintenance quick and simple.
- Leveling Feet
|